Systems and services.

All executed by our own supervised teams, and designed to the National Building Code, the applicable Indian Standards, and the requirements of the local Fire Brigade.

01

Hydrant and wet riser systems

Underground and terrace tanks, pump room, ring main, wet risers, landing valves, hose reels and yard hydrants. Sized from hydraulic calculation, then pressure tested before commissioning.

Scope
Hydraulic calculation, pump and tank sizing
Ring main and riser layout, shop drawings
Pump room fabrication and electrical interlock
Landing valves, hose reels and yard hydrants
Pressure testing, flow testing and commissioning
Suits
High rise residential and commercial towers, hospitals, hotels, schools, industrial units and warehouses.
Designed to
National Building Code Part 4, IS 3844, IS 13039, and local Fire Brigade requirements.
02

Automatic sprinkler systems

Wet and dry networks laid out to the occupancy classification, with the head spacing, pipe sizing and water supply that the classification demands.

Scope
Occupancy classification and hazard assessment
Head layout, pipe sizing and hanger detailing
Basement and car park protection
Alarm valves, flow switches and zone control
Flushing, testing and handover records
Suits
Basements and car parks, hotels, malls, warehouses, hospitals and high rise floors.
Designed to
National Building Code Part 4, IS 15105, and local Fire Brigade requirements.
03

Fire detection and alarm

Conventional zoned panels through to analogue addressable systems that report the exact detector in seconds, and VESDA aspirating detection for critical spaces.

Scope
Analogue addressable intelligent panels
Smoke, heat and multi criteria detection
VESDA very early smoke detection
Manual call points, sounders and response indicators
Cause and effect programming and demonstration
Suits
Data and server rooms, archives, switch rooms, hospitals, hotels, schools and process areas.
Designed to
National Building Code Part 4, IS 2189, and manufacturer certification.
04

Gas and special suppression

Total flooding CO₂ and inert gas for rooms where water would do more damage than the fire, with high and medium velocity water spray for transformer and process areas.

Scope
CO₂ total flooding systems
Inert gas clean agent flooding
High and medium velocity water spray
Kitchen hood wet chemical suppression
Cylinder banks, nozzles, release panels and interlocks
Suits
Server and switch rooms, transformer enclosures, archives, process and tank farm areas, and commercial kitchens.
Designed to
National Building Code Part 4, IS 15493, and manufacturer design software.
05

Extinguishers, refilling and AMC

Supply and installation of extinguishers of every type, refilling on schedule, and annual maintenance of installed systems with written test records.

Scope
Extinguishers in ABC, CO₂, foam and water types
Refilling, hydro testing and replacement
Annual maintenance of installed systems
Pump, valve and detector testing with records
Log books and documentation for inspection
Suits
Societies, hospitals, schools, hotels, offices and factories. Any building with a system already installed.
Designed to
IS 2190, IS 15683, and an annual test schedule agreed at contract stage.
06

Consultancy and Fire Brigade NOC

Statutory review at drawing stage, shop drawings and calculations for submission, inspection support, and follow through until the No Objection Certificate is issued.

Scope
Statutory review at drawing stage
Shop drawings and calculations for submission
Provisional and final NOC documentation
Inspection support and demonstration to the authority
Handover file, test certificates and as built drawings
Suits
Developers and owners at approval stage, and buildings regularising an existing installation.
Designed to
National Building Code, and the Maharashtra Fire Prevention and Life Safety Measures Act.

Tell us the height and the occupancy, and we will tell you what the code requires.

Call +91 80907 08089